At IPL, CAMASTER abends with a S0C4 in module CASRVSYM or CAMCRCVY and produces the CAS9125E error message.
search cancel

At IPL, CAMASTER abends with a S0C4 in module CASRVSYM or CAMCRCVY and produces the CAS9125E error message.

book

Article ID: 38618

calendar_today

Updated On:

Products

CIS COMMON SERVICES FOR Z/OS 90S SERVICES DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS COMMON PRODUCT SERVICES COMPONENT Common Services Datacom/AD CA ECOMETER SERVER COMPONENT FOC Easytrieve Report Generator for Common Services INFOCAI MAINTENANCE IPC UNICENTER JCLCHECK COMMON COMPONENT Mainframe VM Product Manager CHORUS SOFTWARE MANAGER CA ON DEMAND PORTAL CA Service Desk Manager - Unified Self Service PAM CLIENT FOR LINUX ON MAINFRAME MAINFRAME CONNECTOR FOR LINUX ON MAINFRAME GRAPHICAL MANAGEMENT INTERFACE WEB ADMINISTRATOR FOR TOP SECRET Xpertware Compress Data Compression for MVS Compress Data Compression for Fujitsu

Issue/Introduction

Issue:

At IPL, CAMASTER abends with a S0C4-3B or S0C4-10 in module CASRVSYM or CAMCRCVY and produces the error message:

CAS9125E - INVALID DATA: * SEVERE ERROR, CHECK CAIRIM GUIDE * -

 

Environment:  

  • z/OS 2.2 or z/OS 2.1 at current RSU levels
  • CA Common Services r14.1

 

Cause: 

When a CA product uses the CAMASTER Symbol Substitution Service or Metal C Recovery Services, CAMASTER may abend with a S0C4 in module CASRVSYM or CAMCRCVY.     

 

Resolution:

Apply PTF RO78180 to the system.

 

Additional Information:

PTF RO78180 updates the CAMASTER PC Services to prevent a potential reference to storage that may be unavailable.  This PTF is also required for CA Common Services r14.1 compatibility with z/OS 2.2.