Tenant guest OS Vms experiencing timeouts to vSAN file services share
book
Article ID: 385943
calendar_today
Updated On:
Products
VMware vSAN
Issue/Introduction
- Tenants using a guest OS linked to a vSAN file services file share experience occasional timeouts to the share.
- The following messages are logged at vdfsd-server.log
2024-12-12T09:30:40.322Z|f-2-000000043|ADM_SLOW: TupleCacheAdmCtrlMgr: request waited 7.0 sec for numUnits=4190544
Cause
- The txn flush logic in VDFS experiences high latency
- This in turn causes the timeouts at the guest OS level
Resolution
- This is a known issue and Broadcom engineering is working to fix it in later versions
Workaround
- Split the workload to multiple NFS shares. If the issue persists please open a Support Case with Broadcom Support
Feedback