Any configuration change for Edge by VCO, should show events but this events does not contain the changes was made.
For example, updated the Edge configuration in security parameter. When Events of Edge was checked, events related to these changes were invisible. Instead, only profile update events. However, when open these events, there is no information present. This behavior is started with 6.1 VCO
-Configuration change example was as below:
Events is showing only profile update events
When this event is opened, no details about the change was made is available as a JSON format
SD-WAN VCO/VECO
SD-WAN VCE
There is a new product Enhancement introduced in this area of not showing configuration change in JSON format by default.
That change was introduced as part of internal enhancement by Engineering team
This Behavior is expected starting from 6.1 VCO
To circumvent it, we need to set specific system properties in VCO properties to true in order to get event Details for enterprise events:
vco.enterprise.events.configuration.diff.enable
Note: The system properties would resolve the behavior up to extend when changes are small enough and captured in the difference, but If they are large, then there won't be any difference