Any configuration changes made to Edge via VCO should trigger events, but these events do not reflect the changes that were actually made.
For example, when the Edge configuration was updated in the security parameters, the related events did not appear in the Edge event logs. Instead, only profile update events were visible. However, upon reviewing these events, no details about the changes were found. This issue began with the release of VCO 6.1.
An example of the configuration change is shown below:
Events is showing only profile update events
When this event is opened, no details about the change was made is available as a JSON format
SD-WAN VCO/VECO
SD-WAN VCE
A new product enhancement has been introduced, which by default prevents configuration changes from being displayed in JSON format.
This change was implemented as part of an internal enhancement by the Engineering team.
This behavior is expected from VCO 6.1 onwards.
To circumvent it, we need to set specific system properties in VCO properties to true in order to get event Details for enterprise events:
vco.enterprise.events.configuration.diff.enable
Note: The system properties would resolve the behavior up to extend when changes are small enough and captured in the difference, but If they are large, then there won't be any difference