Network and flood protection settings numbers do not match with the CPS values on the datasheet for 720/740 models.
search cancel

Network and flood protection settings numbers do not match with the CPS values on the datasheet for 720/740 models.

book

Article ID: 385357

calendar_today

Updated On:

Products

VMware VeloCloud SD-WAN

Issue/Introduction

Customer is testing network and flood protection settings and is setting the trigger at 25 percent, what they notice is that the number the flood triggers at is much less than the numbers based on the datasheet numbers provided by broadcom.

Environment

Network and flood protection is enabled.

Cause

Issue is related to a bug under reference 156637, numbers of the platform.JSON for CPS do not match the numbers in the datasheet for 720 and 740 models.

https://docs.vmware.com/en/VMware-SD-WAN/5.2/VMware-SD-WAN-Administration-Guide/GUID-9943A130-CD6C-4653-AB36-6A396EA8C677.html#test-results-3.

Issue is hitting version 5.2.4.1

Resolution

Issue will be resolved in 5.4.1.0, 6.0.1.0, 5.2.4.2, 5.2.6.2