Toaster Message TMA-0905 has the incorrect termination date. It is one day after the actual termination date.
STR:
1. Set a timesheet resource's termination date to some date in the future.
Example: Jan 5, 2025. This is the last day of a time reporting period, but it does not matter.
2. Log in as that user and go to My Timesheet
3. Select time period starting Jan 6. - Note that you can open that timesheet but cannot enter any hours.
If the termination date is in the middle of the week, time can be entered for days before the termination date.
4. Now go to the next time period (2 after termination date). In this scenario Jan 13, 2025
Expected Result: Toaster Message TMA-0905 should show the termination date of 1/5/2025
Actual Result: Message shows termination date of 1/6/2025. Once this error appears the date picker cannot be changed. A page refresh is needed.
Workaround: None. Refresh the page to continue working.
16.2.3 16.3
Reported as DE160800. Fix targeted for 16.3.2