SDDC SOS health check: The test “GENERAL-CHECK” has a status of COMPLETED_WITH_FAILURE : Node Ring Topology Status
book
Article ID: 384848
calendar_today
Updated On:
Products
VMware SDDC ManagerVCF - MCOE - SDDC
Issue/Introduction
The test “GENERAL-CHECK” has a status of COMPLETED_WITH_FAILURE.
One of the GENERAL-CHECK tests shows below message.
name : ** SDDC: PSC Ring Topology Status status : FAILED
Environment
VMware Cloud Foundation 4.x
VMware Cloud Foundation 5.x
VMware Cloud Foundation 5.1.x
Cause
The Error is related to failed while Workload provisioning an invalid vCenter Server may have been added to the PSC ring topology.
Make sure that It is important to do agreement in sequence and register with the PSC Nodes when creating the next one.
Resolution
Validate the vCenter replication partners and their agreements, remove agreements with invalid Node using vdcrepadmin tool. We can unregister any invalid Node from the ring using cmsso-util tool.