VeloCloud - QoS Bandwidth incorrect after gateway certificate renewal
search cancel

VeloCloud - QoS Bandwidth incorrect after gateway certificate renewal

book

Article ID: 384454

calendar_today

Updated On:

Products

VMware VeloCloud SD-WAN

Issue/Introduction

After gateway's certificate renewal, qos_net bandwidth cap to remote edge peer becomes 0. Issue may cause unexpected QoS drops for downstream traffic from gateway to edge. 

Environment

VeloCloud SD-WAN gateway release 5.1/5.2/5.4/6.0

 

 

Resolution

The issue is identified as a defect tracked under #155042.

 

In order to verify the BW Cap on gateway, blow command can be used.

debug.py --qos_net <peer_id> all stats

 

Workaround : Manually run a bandwidth test on edge will fix the issue or configuring edge as certificate deactivated mode will avoid the issue.

Additional Information

The issue is identified as a defect tracked under #155042