FIB updates are causing N-S outage(~2-5 secs) during NSX manager upgrade
search cancel

FIB updates are causing N-S outage(~2-5 secs) during NSX manager upgrade

book

Article ID: 384031

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

During phase-3 upgrade(manager upgrade), we see FIB update happening on edge node which caused N-S outage of ICMP in the range of 2-5 secs on different uplink of active edge node.

2024-**-**T03:09:19.341Z ****-nsx01.***.*** NSX 7826 FABRIC [nsx@6876 comp="nsx-edge" subcomp="datapathd" s2comp="dpc-pb" tname="dp-ipc18" level="INFO"] Delete lrouter ********-****-****-****-**************'s FIB entry for **.**.**.250/32
2024-**-**T03:09:19.763Z ****-nsx01.***.*** NSX 7826 FABRIC [nsx@6876 comp="nsx-edge" subcomp="datapathd" s2comp="dpc-pb" tname="dp-ipc18" level="INFO"] Update lrouter********-****-****-****-**************'s FIB entry for **.**.**.250/32

Environment

VMware NSX-T Data Center

Cause

After successful upgrade of MP, there will be full sync between MP-CCP and between CCP - TNs delta sync. On edge nodes, I can see delete FIB process first and later create processed and because of that there is datapath outage for 2-3 seconds.

Resolution

Fixed in the following versions and above:

NSX 3.2.3
NSX 4.1.x