Abends S0C3 running STATESET after having applied PTF LU14722
search cancel

Abends S0C3 running STATESET after having applied PTF LU14722

book

Article ID: 383501

calendar_today

Updated On:

Products

OPS/MVS Event Management & Automation

Issue/Introduction

After having applied the enhancement PTF LU14722 the following errors may occur when executing STATESET as a TSO/REXX.

For example:

!STATESET resource MODE(PASSIVE)

Errors produced:

OPS3092H System abend code 0C3, reason code 00000003.   
OPS3092H Abend in external function OPSCLEDQ.  
IEA995I SYMPTOM DUMP OUTPUT              
SYSTEM COMPLETION CODE=0C3  REASON CODE=00000003 
 TIME=09.07.48  SEQ=01729  CPU=0000  ASID=0028  
 PSW AT TIME OF ERROR  478D1000   9BD02524  ILC 4  INTC 03  
   ACTIVE MODULE           ADDRESS=00000000_1BD024B0  OFFSET=00000074 
   NAME=OPSCLEDQ                                                      

Environment

OPS/MVS 

Resolution

Published PTF LU15371 corrects PE PTF LU14722