Fields such as the project Description and Objective fields are configured.
When the field is updated, the focused content reverts back to what was input prior to the field update.
STEPS TO REPRODUCE:
1. Configure a project blueprint
2. Place the fields Description and Objective on the Properties page.
3. Enter content either by typing or copy-pasting in either field.
Expected: Content in field updated
Actual: Content in field removes the change, reverts back to prior content.
Note: If the issue is not reproducible, force it to be by going to the other field and vice versa.
The generated HAR file shows the 2 PUT calls (the updated content and the prior content).
DE156922,DE153050
This is a work-in-progress and is being tracked internally as a feature.