VeloCloud Edge - MAC address flapping on switch upstream from HA pair of edges
search cancel

VeloCloud Edge - MAC address flapping on switch upstream from HA pair of edges

book

Article ID: 383435

calendar_today

Updated On:

Products

VMWare SD-WAN VMware SD-WAN by VeloCloud VMware VeloCloud SD-WAN VMware VeloCloud SD-WAN Edge Appliance VMware VeloCloud SD-WAN with Premier Support

Issue/Introduction

A customer may observe the same MAC address coming from both VeloCloud edge WAN interfaces in an HA pair, on the upstream switch connected to the edges WAN interfaces, causing MAC flapping alerts on the switch.

Environment

High Availability setup.

Software version 4.5.x.

Cause

This can be caused by software defect 129359, as described here and in the 5.2.2 release notes:

Symptom: For a customer enterprise site deployed with a High Availability topology, in rare instances the customer may observe that both the Active and Standby Edges are sending out heartbeat packets on their WAN links with the same MAC address.

Description: When encountered, this issue impacts the upstream switch which may send alerts related to two different flows with the same MAC address coming into the switch. The issue can result from a timing condition that results in the Standby Edge's MAC file not being created and then the Standby Edge tries to recover from this by mistakenly updating its interface MAC addresses to match the Active Edges.

Resolution

Upgrade to software release 5.2.2.x or newer.

As a workaround, rebooting both edges in the HA pair may help. 

Otherwise, the standby edge will need to be removed from the HA pair, reset to factory defaults, then added back to HA.

Additional Information

Please open a support request if needed to verify that this is being caused by issue 129359