A Package is built and cast with return code of 0 but the execution fails with an U806.
search cancel

A Package is built and cast with return code of 0 but the execution fails with an U806.

book

Article ID: 38294

calendar_today

Updated On: 09-23-2024

Products

Endevor Endevor Natural Integration Endevor - ECLIPSE Plugin Endevor - Enterprise Workbench

Issue/Introduction

Running Endevor 18.0 and a Package is built and cast with return code of 0 but the execution fails with the following message:

BC1PBM30: F000 ABEND CODE=U806 NUMBER=0806

What is wrong? 

 

 

 

 

Environment

Release 18.0 
 

Resolution

This is a known problem with Endevor, if you look at the execution of the package you will see the following message:

C1G0228E  UNABLE TO MATCH SUBSYSTEM P999X IN SYSTEM P9999

Please check the subsystems defined in your SCL, there is one defined that does not exist within Endevor.  Correct and resubmit the job.