Non-SDWAN via gateway is empty in the monitor tab of new VCO UI
search cancel

Non-SDWAN via gateway is empty in the monitor tab of new VCO UI

book

Article ID: 382815

calendar_today

Updated On:

Products

VMware VeloCloud SD-WAN

Issue/Introduction

User will not be able to view the monitoring data for NSDs. They will be seeing an empty page.

Environment

VCO 6.0

Cause

Whenever we have a datacenter data without tunnel Mode field, user can see this issue happening.

Resolution

Add the tunnelMode field to all the datacenter data missing tunnelMode field and update the enterprise service or just do some changes on the configure page of NSD via gateway for all the datacenter missing tunnelMode field and save it in the UI.

Additional Information

Issue is tracked under the bug ID 144622. The defect is fixed in the VCO releases 6.0.0.6 and 6.1