OPS/MVS Event Management & Automation

Issue/Introduction

When running ADDRESS USS USSCMD OPS/REXX program ended with RC=56.

OPS3092O ERROR 41 RUNNING TEST, LINE *: BAD ARITHMETIC CONVERSION

Cause

No OPSUSS server was active as USSMIN parameter was set to 0.

Resolution

Set parameter USSMIN to 2 as this is the recommended value. 

Additional Information

Below is the link to doc.