NSX-T UI Displays Edge Associated with Logical Router After Edge Removal
search cancel

NSX-T UI Displays Edge Associated with Logical Router After Edge Removal

book

Article ID: 382135

calendar_today

Updated On:

Products

VMware NSX VMware NSX-T Data Center

Issue/Introduction

  • The NSX-T UI shows that a Bare Metal (BM) Edge is still associated with a Logical Router (LR) even after the Edge has been removed from the cluster.
  • Running the get logical-router command on the BM Edge via SSH as the admin user shows no routers, confirming that the Edge is no longer associated with any Logical Router.

Environment

VMware NSX

VMware NSX-T Data Center

Cause

This issue occurs due to an indexing failure in NSX Manager, which prevents the UI from properly reflecting the updated state of the Edge and its Logical Router association.

Resolution

Workaround

To resolve the issue, perform a resynchronization of the NSX-T indexing components. Follow these steps:

  1. Log in to all three NSX Managers as the admin user.
  2. Run the following commands
    • start search resync policy  
    • start search resync manager  
    • start search resync all

Note:

  • The start search resync all command will temporarily make the NSX Manager UI unavailable for a few minutes. However, this will not impact the dataplane or control plane, and production traffic will not be affected.
  • After running the commands, wait 5–10 minutes for the UI to synchronize with the Edge CLI values.

Additional Information

  • These commands trigger a resynchronization of various NSX-T components to ensure the NSX Manager's configuration is aligned with the actual state of transport nodes, clusters, and edges.
  • If the issue persists after running these commands, consider opening a Support Request with Broadcom Support for further assistance.