Issue/Introduction
There is a need to enable additional logging for the new CCS 12.7 Management Console
Resolution
- Make a backup copy of the web.config file located at <InstallDir>\Symantec\CCS\Reporting and Analytics\CCSWebConsole\
- Edit the web.config file and change the following entry, make sure that the xml file format does not get changed.
stdoutLogEnabled="false
"
to
stdoutLogEnabled="true
"
- Restart the "Symantec Application Server Service"
The new logs will be located at the following location.
<InstallDir>\Symantec\CCS\Reporting and Analytics\CCSWebConsole\logs