When selecting an unmanaged port in in the cisco_ucs probe it returns the following error:
System.Reflection.TargetInvocationException: Property accessor 'Value'
on object 'conf_cisco_ucs.CiscoUcsMetricViewModel' threw the following exception:'string conversion value not found: value=auto
key="EC:ETHERPIO:<DEVICENAME>::sys/switch-B/slot-1/switch-ether/port-##"."operSpeed" type=VALUE' ---> System.Exception:string conversion value not found: value=auto
key="EC:ETHERPIO:<DEVICENAME>::sys/switch-B/slot-1/switch-ether/port-##"."operSpeed" type=VALUE
at conf_cisco_ucs.CiscoUcsMetricViewModel.getDisplayValue(String val, Boolean enforceEnumerationValueFlag)
at conf_probe_ui.MetricViewModel.get_Value()
--- End of inner exception stack trace ---
at
System.ComponentModel.ReflectPropertyDescriptor.GetValue(Objectcomponent)
at
System.Windows.Forms.DataGrindView.DataGridViewDataConnection.GetValue(Int32 boundColumnIndex, Int32 columnIndex, Int32 rowIndex)
Version: 20.4, 23.4
Component: cisco_ucs
This would be normal with a port where a GBIC has never been installed in the port. Due to the nature of the problem, an idea has been created for this. It will be reviewed for future implementation.
https://community.broadcom.com/idea/cisco-ucs-probe-remove-error-when-selecting-a-port-where-a-gbic-has-never-been-installed