Running installation job SAMPJCL member AGJ30APB (APPLY) fails with:
IEW2322I 1220 1 ENTRY CULFDS
IEW2322I 1220 2 INCLUDE SMPLTS(CULLTFDS) SEQ #
IEW2322I 1220 3 INCLUDE TOTALLIB(DATBAS) TYPE=UTIN
IEW2303E 1030 MEMBER DATBAS OF THE DATA SET SPECIFIED BY TOTALLIB COULD NOT BE FOUND.
IEW2322I 1220 4 NAME CULLTFDS(R) MAX ACCEPTABLE RC=0
IEW2456E 9207 SYMBOL DATBAS UNRESOLVED. MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
The RECEIVE job SAMPJCL(AGJ20RCB) ran without commenting out or removing the FMIDs for the CA CULPRIT Interface products.
You must comment out or remove any FMIDs for products you are not installing in the SMP/E jobs (AGJ20RCB, AGJ30APB, and AGJ6ACC).
------------------------------------------------------------------
Delete all datasets except for the SAMPJCL and run the jobs again.
* IMPORTANT NOTE:
Remember before running the RECEIVE (AGJ20RCB), APPLY (AGJ30APB), and ACCEPT (AGJ6ACC) jobs that you
must comment out or remove the FMIDs for CULPRIT Interface products that you are not installing.
CAGJJ02 /*CA Culprit interface for FCS
CAGJJ03 /*CA Culprit interface for IMS
CAGJJ04 /*CA Culprit interface for RDMS
CAGJJ05 /*CA Culprit interface for Total
Proceed following the documentation from section, "Run the Installation Jobs for a Pax Installation" .