Geneve traffic is not properly handle by the edge.
search cancel

Geneve traffic is not properly handle by the edge.

book

Article ID: 380339

calendar_today

Updated On:

Products

VMware VeloCloud SD-WAN Edge Appliance

Issue/Introduction

Geneve traffic is not properly handled by the velocloud edge.

When the geneve tunnel traffic is sent through the edge as transit, edge is dropping the traffic when it is coming on the WAN Underlay.

Environment

Edge will be used as transit for the Geneve traffic.

Cause

When the Geneve traffic is coming through the underlay edge will be dropping the Geneve traffic.

Traffic is placed in the following queue and will not process further.

 

edge:VELH-AU-NSW-EQUINIX(active):~# dispcnt -z -a | grep -i edged-nw.pkttrace.pkt_noqueue
edged-nw.pkttrace.pkt_noqueue = 148328038   
edge:VELH-AU-NSW-EQUINIX(active):~# 

Engineering confirmed this to be the Defect and working on the fix.

Resolution

This issue is fixed in the 6.1 version.