Interface with Auto-Negotiation Disabled Fails to Come UP After Upgrade to 5.2.3.4
search cancel

Interface with Auto-Negotiation Disabled Fails to Come UP After Upgrade to 5.2.3.4

book

Article ID: 380199

calendar_today

Updated On:

Products

VMware SD-WAN by VeloCloud VMware VeloCloud Cloud Web Security VMware VeloCloud SD-Access VMware VeloCloud SD-WAN VMware VeloCloud SD-WAN Edge Appliance

Issue/Introduction

After upgrading to version 5.2.3.4, some users may experience issues with network interfaces failing to come online when auto-negotiation is disabled. This issue is particularly noted with certain Edge (6X0) that have auto-negotiation turned off, as the new Ethernet port settings in 5.2.3.4 force auto-negotiation to remain enabled. This behavior change was introduced in version 5.2.3.4 and is tracked under issue ID 151654. A hotfix has been released to revert this change and restore expected functionality.

Environment

Velocloud Edge 5.2.3.4

Cause

The problem arises from a deliberate change made in version 5.2.3.4, where the Ethernet port settings always keep auto-negotiation enabled, even if the VeloCloud Orchestrator (VCO) requests it to be disabled. This can prevent the link from coming up on switch ports that require auto-negotiation to be disabled.

This change was implemented to address challenges with 720 and 740 platforms, specifically to prevent issues with fixed link modes (such as "1000 fixed" or "2500 fixed") that require auto-negotiation to be enabled.

Resolution

The development team has acknowledged the issue and provided a hotfix for version 5.2.3.4. The changes introduced in version 5.2.3.4 (R5234-20240826-GA-cf74deab77) have been reverted in the hotfix release R5234-20241004-GA-151654-d67c187bca. This hotfix restores the behavior where auto-negotiation settings from the VCO are respected, allowing interfaces with auto-negotiation disabled to function properly.

Steps to resolve:

  1. Upgrade to the hotfix version:
    • Ensure your edge is running R5234-20241004-GA-151654-d67c187bca to resolve the issue.
  2. If the upgrade is not possible:
    • Consider manually enabling auto-negotiation on affected switch ports or interfaces, or consult with your network team to temporarily adjust switch configurations.