Receiving message GENUT001 UTAGLDIN identified and corrected a release mismatch executing Fast Unload
search cancel

Receiving message GENUT001 UTAGLDIN identified and corrected a release mismatch executing Fast Unload

book

Article ID: 37993

calendar_today

Updated On:

Products

Fast Unload for DB2 for z/OS

Issue/Introduction

Executing Fast Unload for Db2 for z/OS (PFU) and receiving the following within the JES message output:

GENUT001 UTAGLDIN identified and corrected a release mismatch.
         Version string passed was 101                        
         DB2 subsystem ssid is at 111 using UTLGLD11   

The PFU execution fails with a COND CODE 08.

Cause

Incorrect specification of SSIDVER and SSIDMODE in SETUPxx member within hlq.CDBAPARM.

Resolution

Trace hlq.CDBAPARM ENVDEF, PTISYSxx, and SETUPxx members to verify what members are being utilized. 
Verify SETUPxx member SSIDVER and SSIDMODE to be correct values for respective SSID.