When running SARBCH, after application of View 14.0 PTF LU13895, if the data in the //SYSIN DD is not LRECL=80, an S013-20 error will occur.
View 14.0
Application of PTF LU13895
Error will occur when data in the SARBCH //SYSIN DD is not LRECL=80.
View 14.0 PTF LU13895 contains a requirement for SARBCH to have LRECL=80, for the data in the //SYSIN DD file, for the control statements.
If a //SYSIN DD file is used that does not have LRECL=80, a S013-20 error will occur.
The solution is to ensure that the //SYSIN DD file has data with LRECL=80.