With the correct syntax (as defined at rel 16.0) nothing happens at Sysview 17.0 when entering the command RULES MQ THR
The threshold defined:
)THRESHOLDS MQSDATA-BUFPOOLS YES
)THRESHOLDS MQSDATA-CHANNELS YES
)THRESHOLDS MQSDATA-DQMGRS YES
)THRESHOLDS MQSDATA-PAGESETS YES
)THRESHOLDS MQSDATA-QMGRS YES
)THRESHOLDS MQSDATA-QUEUES YES
DEFINE MQ_QUEU_DeadLetterDepth
SCOPE =
NAME =.DEAD.=
QUAL =
ATTR =
ENABLED
RULETYPE UPPER
TYPE SYSTEM
TRIGLVL CHANGE
PROBLEM 1
WARNING 1
WARNPCT 100
DURATION 2
PRIORITY 0
CAPLEVEL NONE
CAPEVENT *
CAPTIME 00:15:00
MSG YES
LOG
SMF
OPSMVS OPSMVSEVENT CAGSVS0001
NOACNOTIFY NOACTICKET
IMOD NO IMODNAME *
NOTRAP TRAPDEST *
SUN MON TUE WED THU FRI SAT
TIMEBEGIN 00:00:00
TIMEEND 23:59:59
DESCRIPTION 'Dead letter queue depth '
ENDDEFINE
Sysview release 17.0
The threshold definition is correct, only ptf LU13237 introduced a problem with the MQ thresholds.