Issue/Introduction

Issue: 
Getting Warning messages  in system.log
Pgm nhiTrapServerCmu: Received pdu community has incorrect type
 
Environment:  
ehealth 6.3.2.04 on Windows 2008
 
Cause: 
Ports scanner might be enabled in the environment.
 
Resolution:
In order to suppress these errors, we can disable the NHITRAPSERVERCMUservice or if we are not using it then follow the below steps.
 
Step1)Stop eHealth Services(nhserver stop)
Step2)Add NH_SNMP_LOG_SUPPRESS = Yes Environment variable
Step3) Start eHealth Services(nhserver start)
 
Additional Information:
Fixed in eHealth 6.3.2.06