Getting errors logging on to PanAPT -- IKJ56709I INVALID DATA SET NAME, '<VPFX>.APTDB' 
search cancel

Getting errors logging on to PanAPT -- IKJ56709I INVALID DATA SET NAME, '<VPFX>.APTDB' 

book

Article ID: 376692

calendar_today

Updated On:

Products

PanApt

Issue/Introduction

Getting the following messages when logging on to PanAPT:

 IKJ56709I INVALID DATA SET NAME, '<VPFX>.APTDB'                                
IKJ56701I MISSING dataset name                                                 
APTALLOC-02 Parse error, RC=4, parms='FILE(APTDB)    DATASET('<VPFX>.APTDB')'.
IKJ56709I INVALID DATA SET NAME, '<SPFX>.CABYDATA'                             
IKJ56701I MISSING dataset name                                                 
APTALLOC-02 Parse error, RC=4, parms='FILE(APTMODEL) DATASET('<SPFX>.CABYDATA')
 ***   

Environment

PanAPT 3.2

Resolution

The &DEFVPFX and &DEFSPFX variables in the APT PROC in the CABYCLS0 library needs to be updated with the appropriate data set prefixes: 

SET &SYSASIS = ON                 /* Maintain up/low case in msgs   
SET &DEFVPFX = &STR(<VPFX>)       /* Set default to PRODUCTION files
SET &DEFSPFX = &STR(<SPFX>)       /* Set default to PRODUCTION files