Symptoms:

When I set a CI to maintenance mode manually in SOI it switches to maintenance mode in UIM as expected. But after 2 minutes it changes back into production mode in UIM.

Environment:

SOI 3.3 and SOI 4.0

UIM connector 3.0.71

Cause:

The problem is seen because the default maintenanceModeScheduleDuration in the \CA\Catalyst\CatalystConnector\registry\topology\physical\<hostname>_CatalystConnector\modules\configuration\NimsoftConnector.xml

file is 120000 which are 2 minutes.

Workaround:

You can modify the value for maintenanceModeScheduleDuration to your prefered time. If you leave the value empty

the duration will be 2 months.

stop the Catalyst Container Service on the connector machine after the modification

remove the file <schedule>.ub in the container\data\core folder

start the Catalyst Container Service

 

 

 

 

 

 

 