Datacom MUF fails on startup with: DB01917E - INVALID MIX OF OPTIONS
search cancel

Datacom MUF fails on startup with: DB01917E - INVALID MIX OF OPTIONS

book

Article ID: 37607

calendar_today

Updated On:

Products

Datacom Datacom/AD Datacom/DB

Issue/Introduction

Datacom/DB Multi-user (MUF) startup failed with:

DB01900I - ACCESS NOOPT,ALL 
DB01909E - * - ASTERISK POINTS NEAR ERROR 
DB01917E - INVALID MIX OF OPTIONS - CONFLICT WITH ACCESS OPTION 1
DB01900I - ACCESS OPTIMIZE,1-20,1000,1006,1007 
 
What is needed to correct this?

Cause

This DB01917E error occurred when the HISTORY system database was activated in the MUF startup options:
 
HISTORY  1007
 
Datacom/DB maintenance tightened up the rule that the MUF startup option ACCESS NOOPT must not specify any system database's in the DBID list. The current list of System Database ID number's are 1-20 & 1000-1020

Resolution

Replace "ACCESS NOOPT,ALL" with "ACCESS NOOPT,21-999" to exclude all system DBIDS

Additional Information

ACCESS NOOPT has additional usage restrictions which can be found under the "ACCESS" documentation