COBOL compile error IGYRC5108-U COBOL COMPILER TERMINATING
search cancel

COBOL compile error IGYRC5108-U COBOL COMPILER TERMINATING

book

Article ID: 374970

calendar_today

Updated On:

Products

Endevor Test4z

Issue/Introduction

Endevor or Test4z COBOL compile aborts with message IGYRC5108-U COBOL COMPILER TERMINATING: UNCORRECTABLE PROGRAM INTERRUPT CONDITION.

PP 5655-EC6 IBM Enterprise COBOL for z/OS  6.3.0 P240526 ...   
         IGYRC5108-U   COBOL compiler terminating:  Uncorrectable program interrupt condition.

 PROGRAM CHECK, INTERRUPT CODE 04
 PSW 078D1F00 A26246B0
 REGISTERS 0 - 15:
 2208D26E 00000000 001FE70F 00000012         00138DD0 00000000 00000000 001FE6BC
 00000000 00000000 00131A14 22539230         2208D13C 2208CE80 A2538FAE A253942A
  CURRENT COBOL COMPILER PHASE: IGYCPGEN (STORAGE LOC: A25386E8)
 LAST MODULE RECORDING CONTROL: IGYPTEMP (STORAGE LOC: 22624480)
 INTERRUPT OCCURRED AT STORAGE LOCATION: 006246AC
 CURRENT LINE NUMBER: 053572

 LineID  Message code  Message text
 ...
 Messages    Total    Informational    Warning    Error    Severe    Terminating
 Printed:      20          17              2                               1
 End of compilation 1,  program XXXXXXXX,  highest severity 16.

 

PP 5655-EC6 IBM Enterprise COBOL for z/OS  6.4.0 in progress ...               
         IGYRC5108-U   COBOL compiler terminating:  Uncorrectable program       
                       interrupt condition.                                     
 Messages    Total    Informational    Warning    Error    Severe    Terminating
 Printed:       1                                                          1    
 End of compilation 1,  program YYYYYYYY,  highest severity 16.

 

Environment

Enterprise COBOL 6.3, 6.4

Resolution

For Enterprise Cobol 6.3, remove IBM APAR PH61467 and PTF UI96895.

For Enterprise Cobol 6.4, apply IBM APAR PH61439.