Error CAWA1239E using CAWAFM2 for FileMaster batch processing
search cancel

Error CAWA1239E using CAWAFM2 for FileMaster batch processing

book

Article ID: 374401

calendar_today

Updated On:

Products

File Master Plus

Issue/Introduction

Using CAWAFM2 for FileMaster batch processing the following errors occur:

*** CAWA4106E  INPUT CONTAINS ALL BLANKS AND/OR COMMENTS                   
*** CAWA1239E  Error encountered while converting input SYSIN parm         
*** CAWA1239I  When the Program Name in the JCL is 'CAWAFM2', the input    
*** CAWA1239I    parameter file (DDNAME = SYSIN) is converted to current   
*** CAWA1239I    syntaxes for CA File Master Plus.  An error was           
*** CAWA1239I    encountered during this conversion process.  The input    
*** CAWA1239I    SYSIN parameter file is displayed below.                  

Environment

File Master Plus v12

Cause

CAWAFM2 was previously shipped with much older versions of FileMaster, specifically Version 3.1 and 4.1,
and it had a specific purpose to dynamically convert FileMaster version 2 commands to FileMaster version 3.1 etc.

In release 8.5, support for CAWAFM2 was stopped and it was no longer shipped, as commands were no longer changed based on product version.

Resolution

Program CAWABATC must be used for File Master Plus batch processing.