Server validation fails with E190098 and 401 when adding web service url
search cancel

Server validation fails with E190098 and 401 when adding web service url

book

Article ID: 373938

calendar_today

Updated On:

Products

Autosys Workload Automation

Issue/Introduction

After having added the web services url in the autosys server definition in WCC configuration tab, the validation fails with below error message

Error: E190098 <server_name> (web services validation) - A connection exception was encountered.
https://<hostname>/9443/AEWS returned status 401

 

Environment

Autosys 12.x
WCC 12.x

Resolution

When EEM is connected to Active Directory, the Monitor ID does not require the domain name.
Initially the Monitor Id was specified as

<userid>@domain.com

After specifying Monitor Id : <userid> , the validation of the server was successful.