Generate Aggregated Event Alarm
search cancel

Generate Aggregated Event Alarm

book

Article ID: 372899

calendar_today

Updated On:

Products

DX NetOps

Issue/Introduction

In Performance Management needs to create an aggregated alarm only for 4 or 5 interface from multiple devices

Environment

Performance Management 23.3.8 and higher

Cause

Needs to receive event alarms from a group of aggregated interfaces

Resolution

Example

  • Create an Aggregated Component Interface and select the interface that you want

  • Create a Monitor Profile Aggregated Interface, add the Aggregated Interface Metric Family and add Collection

  • Create a Threshold Profiles Aggregate Interface using Aggregated Interface Metric Family

  • Add the Aggregated Components in Groups

  • Now you can see in Events Display the Threshold Violation event message: