NSX Edge nodes Configuration State is Pending after successful edge failover
book
Article ID: 372060
calendar_today
Updated On:
Products
VMware NSX
Issue/Introduction
- Configuration State shows as 'Pending' instead of 'Success'.
- Node Status is UP in NSX Manager.
- All Edge nodes appear green with no visible errors on the NSX UI.
- All tunnels remain up after an Edge failover.
- Edge failover messages appear in /var/log/syslog, including:
- Edge nodes are reachable from NSX Managers.
- During the failover, a temporary traffic impact was observed. After failover, no impact seen.
Cause
NSX manager services were not properly updating the UI after the Edge HA events. This can lead to stale UI entries.
Resolution
- Restart the manager services using the command
restart service manager
- There is no impact to datapath traffic due to the above.
Feedback
thumb_up
Yes
thumb_down
No