CA 1 TMSINIT JOB : IEFTMS70 6YY-128
search cancel

CA 1 TMSINIT JOB : IEFTMS70 6YY-128

book

Article ID: 371686

calendar_today

Updated On:

Products

CA 1 Flexible Storage

Issue/Introduction

IEFTMS70 6YY-128 OPCODE=00                                  
IEFTMS70 ***** CA 1 ABEND,I3,00 *****                  **   
IDI0034I Fault analysis skipped due to: EXCLUDE option 
IEA995I SYMPTOM DUMP OUTPUT  823                            
SYSTEM COMPLETION CODE=6F2  REASON CODE=00000080            
 TIME=23.45.08  SEQ=00039  CPU=0000  ASID=0064              
 PSW AT TIME OF ERROR  070C1000   8DE23602  ILC 2  INTC 0D  
   NO ACTIVE MODULE FOUND                                   
   NAME=UNKNOWN                                             
   DATA AT PSW  0DE235FC - 00181610  0A0DD70F  D048D048     
   GR 0: 84000000   1: 846F2000                             
      2: 006F2000   3: 80030000                             
      4: 00031000   5: 00032000                             
      6: 008CA010   7: 80030A9C                             
      8: 0000000C   9: 00000000                             
      A: 00CDC000   B: 0DDBED50                             
      C: 008FC818   D: 00033818                             
      E: 00000080   F: 00000080                             
 END OF SYMPTOM DUMP                                        
IEF450I TMSINIT TMSINIT - ABEND=S6F2 U0000 REASON=00000080  
IEF404I TMSINIT - ENDED                               
$HASP395 TMSINIT  ENDED - ABEND=S6F2                  

Environment

Ca V15.0

Cause

Reason: The first record on the Audit data set is not Control Record 4 (TMSCTL#4). This occurs during initialization.

Resolution

Action: If this is the first time CA 1 is being used, it is usually a result of the Audit not having been formatted with TMSFORMT. Otherwise, this is usually the result of the Audit being corrupted by I/O or related problems (such as pack defragmentation if the Audit was not allocated as DSORG=PSU). Follow the procedures for restoring the Audit with TMSFORMT.

Please follow the details mentioned in the manual under the TMSFORMT utility for formatting the Audit Data Set While Tapes are not processing. Please find the link here for all the details.

Note: The value of the AUDIT specified on the SYSIN of the TMSFORMT JCL corresponds to the values of the Number of audit records from the TMSCOPY backup report.