If an external Dependency within a workflow has the option "if the external task was activated with the same logical date as the workflow" selected the else / condition missmatch path is not processed correctly for the option "Wait".
Instead of waiting, the external dependency ends with the state "ENDED_INACTIVE - inactive due to logical date condition of external dependency." leading to the dependent Job running too early.
This was working fine on version 21.0.4 and all prior versions.
Automation Engine 21.0.9 and superior
Defect
Update to a fix version listed below or a newer version if available.
Fix version:
Component(s): Automation Engine
Will be fixed in Automation.Engine 21.0.11 - Released
Will be fixed in Automation.Engine 24.2.0 - Planned release end September 2024
Defect ID: AE-37133
Public Description: A problem has been fixed where external dependencies within a workflow in were not waiting as expected when the "if the external task was activated with the same logical date as the workflow" option was selected. This caused the dependent job to run too early.