LAG MEMBER DOWN alarm in NSX Manager while lag member is up
book
Article ID: 370474
calendar_today
Updated On:
Products
VMware NSX
Issue/Introduction
- NSX version less than 3.2.0
- LAG MEMBER DOWN alarm noticed in NSX Manager UI
- Lag member vmnic is showing UP status in vCenter
- No production impact noticed
Environment
NSX version less than 3.2.0
Cause
Changes happen in transport nodes, NSX SHA side is not updating the event status correctly, causing stale alarm entry.
Resolution
Issue has been fixed in NSX-T 3.2.0 and later releases.
Workaround:
Restart netopad service.
/etc/init.d/netopad restart