LAG MEMBER DOWN alarm in NSX Manager while lag member is up
book
Article ID: 370474
calendar_today
Updated On:
Products
VMware NSX
Issue/Introduction
- NSX version less than 3.2.0
- LAG MEMBER DOWN alarm noticed in NSX Manager UI
- Lag member vmnic is showing UP status in vCenter
- No production impact noticed
Cause
Changes happen in transport nodes, NSX SHA side is not updating the event status correctly, causing stale alarm entry.
Resolution
Issue has been fixed in NSX-T 3.2.0 and later releases.
Workaround:
Restart netopad service.
/etc/init.d/netopad restart