LAG MEMBER DOWN alarm in NSX Manager while lag member is up
search cancel

LAG MEMBER DOWN alarm in NSX Manager while lag member is up

book

Article ID: 370474

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

  • NSX version less than 3.2.0
  • LAG MEMBER DOWN alarm noticed in NSX Manager UI
  • Lag member vmnic is showing UP status in vCenter
  • No production impact noticed

Environment

VMware NSX-T Data Center

Cause

Changes happen in transport nodes, NSX SHA side is not updating the event status correctly, causing stale alarm entry.

Resolution

Issue has been fixed in NSX-T 3.2.0 and later releases.

 

Workaround:

Restart netopad service.

/etc/init.d/netopad restart