Moving Elements into Production and getting the following error:
05.16.04 JOB50687 ICH70001I $ENDEVOR LAST ACCESS AT 05:16:04 ON SATURDAY, JUNE 15, 2024
05.16.04 JOB50687 $HASP373 ENDVJOB1 STARTED - WLM INIT - SRVCLASS BATPSTD - SYS XXXX
05.16.04 JOB50687 IEF403I ENDVJOB1 - STARTED - TIME=05.16.04
05.16.07 JOB50687 IEC036I 002-94,IGC0005E,ENDVJOB1,NDVRBAT,SYS000xx,45AC,Sxxx16, 566
566 iprfx.iqual.PROD.DELTA
05.16.07 JOB50687 +CCSR010E C1SSESTA S002 at 00EFDB48 LMOD IGG019BK CSECT N/A +N/A ENDVJOB1 JS001 NDVRBAT
What does that error mean and how can it be resolved
All supported releases
The IBM Error "IEC036I 002-94,IGC0005E" means that the write would have had to create another member in a PDSE which already contained the maximum allowable number of members. The limit is 522,239 members.
If this error occurs during Endevor Processing please reach out to the Broadcom Support Team to assist you with the best possible resolution for your site.