Getting Error IEC036I 002-94 when moving Endevor Elements
search cancel

Getting Error IEC036I 002-94 when moving Endevor Elements

book

Article ID: 370187

calendar_today

Updated On:

Products

Endevor

Issue/Introduction

Moving Elements into Production and getting the following error: 

05.16.04 JOB50687  ICH70001I $ENDEVOR LAST ACCESS AT 05:16:04 ON SATURDAY, JUNE 15, 2024                                             
05.16.04 JOB50687  $HASP373 ENDVJOB1 STARTED - WLM INIT  - SRVCLASS BATPSTD  - SYS XXXX                                              
05.16.04 JOB50687  IEF403I ENDVJOB1 - STARTED - TIME=05.16.04                                                                        
05.16.07 JOB50687  IEC036I 002-94,IGC0005E,ENDVJOB1,NDVRBAT,SYS000xx,45AC,Sxxx16,  566                                               
   566             iprfx.iqual.PROD.DELTA                                                                                          
05.16.07 JOB50687  +CCSR010E C1SSESTA S002 at 00EFDB48 LMOD IGG019BK CSECT N/A +N/A ENDVJOB1 JS001 NDVRBAT    

What does that error mean and how can it be resolved

Environment

All supported releases

Resolution

The IBM Error "IEC036I 002-94,IGC0005E" means that the write would have had to create another member in a PDSE which already contained the maximum allowable number of members. The limit is 522,239 members. 