Connect to <host IP>:443 [/<host IP>] failed: Connect timed out (Workflow:Copy file from vCO to guest / Scriptable task (item1)#13
book
Article ID: 370096
calendar_today
Updated On:
Products
VMware Aria Suite
Issue/Introduction
When running workflow Copy file from vCO to guest, the workflow fails with error: Connect to <host IP>:443 [/<host IP>] failed: Connect timed out (Workflow:Copy file from vCO to guest / Scriptable task (item1)#13
When running workflow Copy file from vCO to guest, the workflow fails with error: Permission denied on file '/etc/temp/RedMe.txt' , right read not allowed (Workflow:Copy file from vCO to guest / Scriptable task (item1)#13)
Environment
Aria Automation Orchestrator
Orchestrator Cloud Proxy for VMware Cloud
Cause
After deploying the cloud proxy to the customer's VMC environment, no exceptions were set up within NSX Manager to allow IP traffic to pass from the Cloud Proxy to the ESXi hosts where the VM's lived.