Issue:

Following an IPL of our system, we get an abend in MSMMUF:

 

06.55.11 STC08249 MSMMUF:DB00248I - PARM PGMDT=20100101 DBSRPPR(VIEWBND ) 2013/03/21-11.46 14 RO56439 

06.55.11 STC08249 MSMMUF:DB00271I - AREAEV -YES, DATAFS -YES, DATAHU -YES, SU - NO 

06.55.11 STC08249 MSMMUF:DB00226I - MULTI-USER ACTIVATED XCF SUPPORT (RIMF20,CSM60) 

06.55.11 STC08249 MSMMUF:DB00260E - CCI ERROR - INIT 0004 0000 00 00000 

06.55.11 STC08249 MSMMUF:DB00223E - MULTI-USER UNABLE TO ACTIVATE CCI, FDBK = 14,00000114 

06.57.43 STC08249 MSMMUF:DB00239I - MUF TERMINATION, START PROGRAM ABEND 

06.57.43 STC08249 MSMMUF:DB00281I - MUF CLEANUP MSMDBSRV 0 1 D032372DFB889069 POST 86(186) 

06.57.43 STC08249 MSMMUF:DB00258I - MULTI-USER ENDING XCF SUPPORT (RIMF20,CSM60) 

06.57.43 STC08249 CCSR010E DBMUFPR U0004 at 16B02268 LMOD DBMUFPR CSECT DBMUFPR +002268 MSMMUF N/A MSMMUF 

 

A subsequent restart of  MSMMUF resolves the problem.

 

Environment: 

Applies to all supported ZOS supported environments using  MSM/CHORUS SOFTWARE MANAGER.

 

Cause:

CAICCI/ENF is  not active  before the  MSMMUF is started.

 

Resolution: 

CCIMVS must be active on the system before DATACOM STARTS.

ENF starts the CCI SUBSYSTEM:

CAS9626I - CAICCI Subsystem is operational

 

If you have a console mgr product (like OPSMVS), add a rule so  that the MSMMUF will not start until ENF issues CAS9626I.

 

Additional Information: 

Please refer to the DATACOM r15.0 Message Reference Guide for more information on  the error message DB00260E.

 

 

 

Environment

Release:
Component: MSM