WAN Links shown as down in VCO
search cancel

WAN Links shown as down in VCO

book

Article ID: 368142

calendar_today

Updated On:

Products

VMware VeloCloud SD-WAN Edge Appliance

Issue/Introduction

A customer may observe that the WAN links on a VMware SD-WAN Edge are intermittently showing as down and then up on the Monitoring and Events page of the VMware SASE Orchestrator UI, with the potential the Edge may become unresponsive and fail to pass traffic until it is manually rebooted, or the Edge can experience a Dataplane Service failure and restart.

Symptoms-
A. An edge can become unresponsive and unreachable through the Orchestrator, which requires an on-site reboot/power cycle.
B. An edge can trigger an Edge service failure with a core file generated, with the Edge restarting to recover.

Environment

Edge software version 451 or lower versions 

Cause

This is an Edge memory leak issue encountered when the Edge Dataplane Service cannot open shared memory, causing stale PIs. This in turn causes open file descriptor exhaustion which will initially impact WAN links

Resolution

This issue is caused by known software issue #125421
This defect is fixed in 4.5.2.2, 5.2.2, 5.4

For more information please see VMware SD-WAN Software Upgrade FAQs

Additional Information

Workaround - 

If first observing this issue, schedule an Edge service restart in a maintenance window before the problem worsens