On a VMware SD-WAN Enhanced HA set up, after a factory reset is done on the 2 boxes, the links in the standby unit might not be visible from the VCO Edge Monitor Page:
However the paths will still be up through the link:
Issue is caused by defect ID: 122717: Spurious netlink messages can cause the wan link on standby to go down
When hard reset is done in an enhanced HA setup, the standby edge's WAN link (the USE_PEER link) can go down. This is because of a spurious netlink down message in the active edge.
Issue ID: 122717 is resolved VMWare SD-WAN edge releases:
For information on how to upgrade please check the following article: VMware SD-WAN Software Upgrade FAQs