In some cases, HCX Network Extension High Availability (NE HA) Failover can happen more often than expected in a busy network that is prone to occasional packet loss.
HCX NE HA periodically transmits Bidirectional Forwarding Detection (BFD) UDP packets as a heartbeat mechanism between the active and standby NE appliance at the same local site.
When the sustained loss of these packets is detected it will trigger a standby to active NE failover.
The default failover detection time depends on the HCX version and Service Mesh (SM) configuration:
| HCX Version | Service Mesh (SM) Type | BFD Threshold / Interval | Detection Time | Script Supported |
|---|---|---|---|---|
| 4.9.1+ | All | 6 heartbeats * 250ms | 1.5 seconds | Yes |
| 4.10+ | All | 60 heartbeats * 250ms | 15 seconds | Yes |
| 9.0+ | All | 60 heartbeats * 250ms | 15 seconds | Yes |
| 9.1+ | Non-Enhanced | 60 heartbeats * 250ms | 15 seconds | Yes |
| 9.1+ | Enhanced | 3 heartbeats * 1000ms | 3 seconds | No |
HCX NE HA uses two independent BFD heartbeat streams to prevent false failovers. A failover only occurs if both streams detect sustained packet loss simultaneously.
NE HA is designed to send two independent BFD heartbeat streams between the active and standby NE appliance at the same local site.
One BFD stream is sent between the NE management interfaces on the active and standby NE appliance at the same local site and the other BFD stream is sent between the NE uplink or the HCX Intrasite Control interfaces for non-enhanced and enhanced appliances, respectively, on the active and standby NE appliance at the same local site. If a period of sustained packet loss is only experienced on one of the interfaces, either the management or uplink / Intrasite Control but not both, then no NE HA failover will take place. This is to avoid false positives where the NE appliance is not truly down. Sustained packet loss must be detected by both BFD streams simultaneously to trigger a standby to active NE failover.
The dual BFD heartbeat fail safe may not work as planned however when a shared single interface is used on an NE appliance for both management and uplink / Intrasite Control. In this scenario, a period of sustained packet loss may impact both BFD streams since they share the same interface. Because of this, it is recommended to always use separate management and uplink / Intrasite Control interfaces on an NE appliance that is configured for HA.