The following event is being generated when Spectrum processes the Southbound Gateway traps:
Device XXXXXXX of type EventAdmin - Error processing event 0xfffa023a - Details: The trap does not specify a target SPECTRUM model. A trap can specify a target SPECTRUM model by ID, name, or IP address.
Spectrum: Any version
The 1.3.6.1.4.1.2544.1.13.1.1.1.9 varbind value is missing in the trap.
This is your AlertMap file for Southbound Gateway implementation:
# ADVA - Network Alarm Device Name
1.3.6.1.4.1.2544.1.13.1.1.6.1 0xfffa023a 1.3.6.1.4.1.2544.1.13.1.1.1.9(1,0)\
# Equipment IPAddress
1.3.6.1.4.1.2544.1.13.1.1.1.10(201,0)\
# Event ID
1.3.6.1.4.1.2544.1.13.1.1.1.3(202,0)\
# Interface Name
1.3.6.1.4.1.2544.1.13.1.1.1.11(202,0 \
# Alarm detail
1.3.6.1.4.1.2544.1.13.1.1.1.16(203,0)\
# Circuit
1.3.6.1.4.1.2544.1.13.1.1.1.27(204,0)
The value of varbind 1.3.6.1.4.1.2544.1.13.1.1.1.9 is mapped to variable 1 which is the target model where the event is generated on.
Contact the administrator of the device that is sending the trap with missing varbind to figure out the issue.