Question:
What is causing this SMP/e GIM20301S syntax error and RC 12 for the APPLY of the base product after I added the BYPASS for the HOLDERROR(s) that the APPLY CHECK indicated?
APPLY
CHECK /*** Remove to APPLY all functions ***/
GROUPEXTEND(NOAPARS NOUSERMODS)
SELECT (
CABDF00 /* CA-Datacom/DB */
CAADF00 /* CA Datacom Datadictionary */
CAVEF00 /* CA Datacom SQL */
CADQF05 /* CA Dataquery for CA Datacom */
CAZNF00 /* CA Datacom Presspack */
CBAPF00 /* CA Datacom Fast Restore */
CAADF05 /* CA Datacom Datadictionary */
CADQF00 /* CA Dataquery for CA Datacom */
)
BYPASS(
HOLDERROR(
AC80958,
BC80958,
CC80958,
DC80958,
EC80958,
FC80958,
GC80958,
HC80958,
IC80958,
AC78136,
BC78136,
CC78136,
DC78136,
EC78136,
FC78136,
GC78136,
HC78136
)
.
GIM20301S ** THERE IS A SYNTAX ERROR IN THE COMMAND AT COLUMN 03.
GIM20501I APPLY PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12.
Answer:
The above SMP/e syntax that was added was missing the pairing right parentheses at the end:
BYPASS(
HOLDERROR(
AC80958,
BC80958,
CC80958,
DC80958,
EC80958,
FC80958,
GC80958,
HC80958,
IC80958,
AC78136,
BC78136,
CC78136,
DC78136,
EC78136,
FC78136,
GC78136,
HC78136
) )
.