During Netmaster initialization the following message appears:
BPXF274I FILE SYSTEM NETMIP.IGP1.U.HOMEDIR.ZFS FAILED to MOUNT RETURN CODE = 00000099, REASON CODE = EF096150
There may be no discernible impact to the active region.
Resolution:
The hFS or zFS files related to the /home directory for the OMVS security segment of the Netmaster userid are not accessible on that LPAR at startup.
Issue the console command
D OMVS,MF
to see if this is the only file system impacted.
The response shows all mount or file system move failures. You will receive a display that looks something like
D OMVS,MF
BPXO058I 09.30.57 DISPLAY OMVS 346
OMVS 000E ACTIVE OMVS=(P1)
SHORT LIST OF FAILURES:
TIME=08.11.11 DATE=2005/08/17 MOUNT RC=0099 RSN=EF096150
NAME=ZOS17.TMP.ZFS
TYPE=ZFS
PATH=/SYSTEM/tmp
PLIB=BPXPRMZG
Investigate why that is the case.
Possible causes include
- the proper DASD were not brought online at IPL
- the directory is defined to DASD not accessible on this system.