Title: Alarm for uplink is going down Event ID: transport_node_health.transport_node_uplink_down
Alarm Description:
Purpose: Monitoring uplink status on Esxi, KVM and Bare Metal Server; Please notice that KVM is unsupported from 4.0.0 release.
Impact: Uplink down will significantly impact on connectivity and traffic flow of network.
Environment
VMware NSX-T Data Center VMware NSX
Resolution
Steps to resolve For 3.2.0 and higher
Recommended Action:
Check the physical NICs' status of uplinks on hosts.
In the NSX UI navigate to "System | Fabric | Hosts | Clusters" or "System | Fabric | Hosts | Other Nodes" or "System | Fabric | Hosts | Standalone".
In the Nodes list of specific cluster or "Other Nodes" tab or "Standalone" tab, check the Status column. Find the Transport node with the degraded or down Node Status.
Select "<transport node>| View Details | Monitor". Check the status details of the PNIC/BOND which is reporting degraded or down. To avoid a degraded state, ensure all uplink interfaces are connected and up regardless of whether they are in use or not.