Title: Alarm for edge flow cache deactivated
Event ID: edge_health.flow_cache_deactivated
Alarm Description
- Purpose: The purpose of this alarm is to notify users when flow cache is disabled.
- Impact: Flow cache being disabled leads to potentially impacting the overall edge throughput.
Cause
Flow cache is disabled on NSX Edge node
Resolution
Steps to Resolve
For 4.1.1 and higher
Recommended Action:
This alarm is automatically resolved upon re-enabling of flow cache.
- To enable flow-cache on the Edge node to run '
set dataplane flow-cache enabled
' Edge CLI.
- Restart dataplane after Flow Cache is enabled using '
restart service dataplane
' Edge CLI.