Cold migrations using Advanced Cross vCenter vmotion or Import VM fails at 39%
search cancel

Cold migrations using Advanced Cross vCenter vmotion or Import VM fails at 39%

book

Article ID: 344918

calendar_today

Updated On:

Products

VMware vCenter Server

Issue/Introduction

Symptoms:
  • Migrating or importing a powered-off VM into a new vCenter fails at 39%
  • Messages in /var/run/log/hostd.log of the source ESXi host indicate that the NFC connection to the destination host failed
2022-06-16T18:57:54.902Z info hostd[2104144] [Originator@6876 sub=Vimsvc.TaskManager opID=l38fyg4u-75219-auto-1m1g-h5:70016369-4e-02-gusu4 user=vpxuser:DOMAIN\user] Task Created : haTask--nfc.NfcManager.copy-1768912663

2022-06-16T18:59:09.967Z info hostd[2103333] [Originator@6876 sub=Libs opID=l38fyg4u-75219-auto-1m1g-h5:70016369-4e-02-gusu43 user=vpxuser:DOMAIN\user] Cnx_Connect: Error message: Failed to connect to server 10.10.10.10:902
2022-06-16T18:59:09.967Z warning hostd[2103333] [Originator@6876 sub=Libs opID=l38fyg4u-75219-auto-1m1g-h5:70016369-4e-02-gusu43 user=vpxuser:DOMAIN\user] [NFC ERROR]NfcNewAuthdConnectionEx: Failed to connect: Failed to connect to server 10.10.10.10:902
2022-06-16T18:59:09.967Z warning hostd[2103333] [Originator@6876 sub=Libs opID=l38fyg4u-75219-auto-1m1g-h5:70016369-4e-02-gusu43 user=vpxuser:DOMAIN\user] [NFC ERROR]NfcNewAuthdConnectionEx: Failed to connect to peer. Error: Failed to connect to server 10.10.10.10:902
2022-06-16T18:59:09.967Z warning hostd[2103333] [Originator@6876 sub=Libs opID=l38fyg4u-75219-auto-1m1g-h5:70016369-4e-02-gusu43 user=vpxuser:DOMAIN\user] [NFC ERROR]NfcEstablishAuthCnxToServer: Failed to create new AuthD connection: Failed to connect to server 10.10.10.10:902
2022-06-16T18:59:09.967Z warning hostd[2103333] [Originator@6876 sub=Libs opID=l38fyg4u-75219-auto-1m1g-h5:70016369-4e-02-gusu43 user=vpxuser:DOMAIN\user] [NFC ERROR]Nfc_BindAndEstablishAuthdCnx3: Failed to create a connection with server 10.10.10.10: Failed to connect to server 10.10.10.10:902
2022-06-16T18:59:09.967Z error hostd[2103333] [Originator@6876 sub=NfcManager opID=l38fyg4u-75219-auto-1m1g-h5:70016369-4e-02-gusu43 user=vpxuser:DOMAIN\user] Unable to connect to NFC server: Failed to connect to server 10.10.10.10:902


Environment

VMware vCenter Server 7.0.x
VMware vCenter Server 6.7.x
VMware vCenter Server 6.5.x

Cause

This failure occurs when port TCP 902 is blocked between the source host and the destination host.

Note that cold migrations are considered provisioning traffic and by default go over the management interface. However, if a dedicated provisioning vmkernel interface is configured, it will use this instead.

Resolution

To correct this issue, remove the firewall rule or network block which is stopping TCP 902 traffic between the hosts.