Unable to see the shared LUN presented from the EqualLogic iSCSI array for VMware ESXi
book
Article ID: 344851
calendar_today
Updated On:
Products
VMware vSphere ESXi
Show More
Show Less
Issue/Introduction
Symptoms:
When scanning the iSCSI HBA, the Equalogic iSCSI presented LUNs do not appear
In the vmkernel.log file, you see entries similar to:vm2 vmkernel: 0:00:49:27.506 cpu2:4284)WARNING: iscsi_vmk: iscsivmk_ConnReceiveAtomic: Conn [CID: 0 L: 10.0.30.50:52227 R: 10.0.30.12:3260] vm2 vmkernel: 0:00:49:27.508 cpu2:4284)WARNING: iscsi_vmk: iscsivmk_ConnReceiveAtomic: vmhba33:CH:0 T:2 CN:0: Failed to receive data: Connection closed by peer vm2 vmkernel: 0:00:49:27.508 cpu2:4284)WARNING: iscsi_vmk: iscsivmk_ConnReceiveAtomic: Sess [ISID: TARGET: (null) TPGT: 0 TSIH: 0] vm2 vmkernel: 0:00:49:27.508 cpu2:4284)WARNING: iscsi_vmk: iscsivmk_ConnReceiveAtomic: Conn [CID: 0 L: 10.0.30.50:63153 R: 10.0.30.12:3260] vm2 vmkernel: 0:00:49:27.760 cpu2:4284)WARNING: iscsi_vmk: iscsivmk_StopConnection: vmhba33:CH:0 T:0 CN:0: iSCSI connection is being marked OFFLINE
In the vodb.log file of ESXi 5.1 hosts, you see entries similar to:[iscsiCorrelator] 384199949us: [vob.iscsi.target.login.error] vmhba38 @ vmk1 failed to login to iqn.2001-05.com.equallogic:<ID> because the target returned a login status of 0202
[iscsiCorrelator] 384200326us: [esx.problem.storage.iscsi.target.login.error] Login to iSCSI target iqn.2001-05.com.equallogic:0<ID> on vmhba38 @ vmk1 failed. Target returned login error of: 0202
Environment
VMware vSphere ESXi 5.1 VMware ESX 4.0.x VMware vSphere ESXi 5.5 VMware ESX Server 3.5.x VMware ESX 4.1.x VMware vSphere ESXi 5.0
Resolution
This error in the vmkwarning.log file indicates that the storage array has closed the connection:
Failed to receive data: Connection closed by peer
To resolve this issue, ensure that
Enable shared access is selected in the Equalogic iSCSI configuration.
Note : You must do this to enable all of the advanced vSphere capabilities that rely on the shared storage. To ensure that Enable shared access is selected in the Equalogic iSCSI configuration:
Select the volume Click Modify Settings . On the Advanced
tab, select Allow simultaneous connections from initiators with different IQN names .
For more information, see Configuring VMware vSphere Software iSCSI With Dell EqualLogic PS Series Storage .
Note : The preceding link was correct as of July 06, 2015. If you find the link is broken, provide feedback and a VMware employee will update the link.
Feedback
thumb_up
Yes
thumb_down
No