SRM reports timeout errors while powering on the virtual machines on a shared recovery site
book
Article ID: 343308
calendar_today
Updated On:
Products
VMware Live Recovery
Issue/Introduction
In a large SRM setup, if a single vCenter Server manages a large number of virtual machines on the shared recovery site, for example 1000 or more, SRM can report timeout errors while powering on the virtual machines on the shared recovery site. The error message is Error:Operation timed out:900 seconds.
Environment
VMware vCenter Site Recovery Manager 5.5.x VMware vCenter Site Recovery Manager 5.1.x VMware vCenter Site Recovery Manager 5.0.x
Resolution
Go to C:\Program Files\VMware\VMware vCenter Site Recovery Manager\config on the SRM Server host machine on the recovery site. For Linux Appliance go to /opt/vmware/srm/conf/vmware-dr.xml
Open the vmware-dr.xml in a text editor.
Increase the default RemoteManager timeout value from 900 to a larger number, for example 1200. <RemoteManager> <DefaultTimeout>900</DefaultTimeout> </RemoteManager>